Drywall (also known as plasterboard, wallboard, gypsum panel, sheet rock, or gypsum board) is a panel made of calcium sulfate dihydrate (gypsum), with or without additives, typically extruded between thick sheets of facer and backer paper, utilized in the construction of interior walls and ceilings.[1] The plaster is mixed with fiber (typically paper and/or fibreglass or asbestos), plasticizer, foaming agent, and various additives that can decrease mildew, increase fire resistance, and lower water absorption.

Drywall construction became prevalent in North America as a speedier alternative to traditional lath and plaster.[2]

The first plasterboard plant in the UK was opened in 1888 in Rochester, Kent.[citation needed] Sackett Board was invented in 1894 by Augustine Sackett and Fred Kane, graduates of Rensselaer Polytechnic Institute. It was made by layering plaster within four plies of wool felt paper. Sheets were 36"36"1/4" (9149146.4mm) thick with open (untaped) edges.[3]

Gypsum board evolved between 1910 and 1930 beginning with wrapped board edges and elimination of the two inner layers of felt paper in favor of paper-based facings. In 1910 United States Gypsum Corporation bought Sackett Plaster Board Company and by 1917 came out with a product they called Sheetrock.[4] Providing efficiency of installation, it was developed additionally as a measure of fire resistance.[5] Later air entrainment technology made boards lighter and less brittle, then joint treatment materials and systems also evolved.[3] Rock lath (gypsum lath) was an early substrate for plaster. An alternative to traditional wood or metal lath, it was a panel made up of compressed gypsum plaster board that was sometimes grooved or punched with holes to allow wet plaster to key into its surface. As it evolved, it was faced with paper impregnated with gypsum crystals that bonded with the applied facing layer of plaster.[6]

In 2002 the European Commission imposed fines totaling 478 million on the companies Lafarge, BPB, and Gyproc Benelux, which had operated a cartel on the market which affected 80% of consumers in France, the United Kingdom, Germany and the Benelux countries.[7]

A wallboard panel consists of a layer of gypsum plaster sandwiched between two layers of paper. The raw gypsum, CaSO42 H2O, is heated to drive off the water then slightly rehydrated to produce the hemihydrate of calcium sulfate (CaSO4 H2O). The plaster is mixed with fibre (typically paper and/or fibreglass), plasticizer, foaming agent, finely ground gypsum crystal as an accelerator, EDTA, starch or other chelate as a retarder, various additives that may decrease mildew and increase fire resistance, and wax emulsion or silanes for lower water absorption. The board is then formed by sandwiching a core of the wet mixture between two sheets of heavy paper or fibreglass mats. When the core sets it is then dried in a large drying chamber, and the sandwich becomes rigid and strong enough for use as a building material.

Drying chambers typically use natural gas today. To dry 1 MSF (1,000 square feet (93m2)) of wallboard, between 1,750,000 and 2,490,000BTU (1,850,000 and 2,630,000kJ) is required. Organic dispersants/plasticisers are used so the slurry will flow during manufacture, and to reduce the water and hence the drying time.[8] Coal-fired power stations include devices called scrubbers to remove sulphur from their exhaust emissions. The sulphur is absorbed by powdered limestone in a process called flue-gas desulphurization (FGD), which produces a number of new substances. One is called "FGD gypsum". This is commonly used in drywall construction in the United States and elsewhere.[9][10]

Drywall panels in the United States are manufactured in 48-inch (1.2m), 54-inch (1.4m) and 96-inch (2.4m) wide panels in varying lengths to suit the application, though 48-inch is by far the most common width. Lengths up to 16 feet (4.9 m) are commonly available, though the most common length is 8 feet (2.4 m). Common panel thicknesses are 12-inch (13mm) and 58-inch (16mm), with panels also available in 14-inch (6.4mm), 38-inch (9.5mm), 3/4-inch (19.0mm) and 1-inch (25.4mm) for specific applications.

In Europe plasterboard is manufactured in metric sizes, with the common sizes being corollaries of old imperial sizes. Most plasterboard is made in 120cm-wide sheets, though 90cm and 60cm wide sheets are also made. 120cm wide plasterboard is most commonly made in 240cm lengths, though 250, 260, 270, 280, 300cm and even longer (if ordered) are commonly available. Thicknesses of plasterboard available are 9.5mm to 25mm.[11]

Plasterboard is commonly made with one of three different edge treatments: tapered edge, where the long edges of the board are tapered with a wide bevel at the front to allow for jointing materials to be finished flush with the main board face; plain edge, used where the whole surface will receive a thin coating (skim coat) of finishing plaster; and, finally, beveled on all four sides, used in products specialized for roofing. However, four-side chamfered drywall is not currently offered by major UK manufacturers for general use.

The term plasterboard is used in Australia and New Zealand.[12] Both countries use the metric system in building, and plasterboard is manufactured in thicknesses of 10mm, 13mm, and 16mm, and sometimes other thicknesses up to 25mm. Panels are commonly sold in 12002400mm, 12004800mm, and 12006000mm sheets. Sheets are usually secured to either a timber or cold-formed steel frames anywhere from 150 to 300mm centres along the beam and 400 to 600mm across members.

Various companies, such as Boral and CSR, manufacture plasterboard under various brand names including Gyprock.

As an alternative to a week-long plaster application, an entire house can be drywalled in one or two days by two experienced drywallers, and drywall is easy enough to use that it can be installed by many amateur home carpenters. In large-scale commercial construction, the work of installing and finishing drywall is often split between the drywall mechanics, or hangers, who install the wallboard, and the tapers and mudmen, or float crew, who finish the joints and cover the fastener heads with drywall compound.[citation needed] Dry wall can be finished anywhere from a level 0 to a level 5, where 0 is not finished in any fashion and 5 is the most "pristine". Depending on how significant the finish is to the customer the extra steps in the finish may or may not be necessary, though priming and painting of drywall is recommended in any location where it may be exposed to any wear.

Drywall is cut to size, using a large T-square, by scoring the paper on the finished side (usually white) with a utility knife, breaking the sheet along the cut, and cutting the paper backing. Small features such as holes for outlets and light switches are usually cut using a keyhole saw or a small high-speed bit in a rotary tool. Drywall is then fixed to the wall structure with nails or drywall screws and often glue. Drywall fasteners, also referred to as drywall clips or stops, are gaining popularity in both residential and commercial construction. Drywall fasteners are used for supporting interior drywall corners and replacing the non-structural wood or metal blocking that traditionally was used to install drywall. Their function serves to save on material and labour expenses, to minimize call-backs due to truss uplift, to increase energy efficiency, and to make plumbing and electrical installation simpler.

Drywall screws heads have a curved taper, which allows them to self-pilot and install rapidly without having to be punched through the paper cover. When finished driving, these screws are countersunk slightly into the drywall. Screws for light-gauge steel framing have an acute point and finely spaced threads. If the steel framing is heavier than 20-gauge, self-tapping screws with finely spaced threads must be used. In some applications, the drywall may be attached to the wall with adhesives.

After the sheets are secured to the wall studs or ceiling joists, the installer conceals the seams between drywall sheets with 'joint tape' and several layers of 'joint compound' (sometimes called 'mud'), typically spread with a taping knife or putty knife. This compound is also applied to any screw holes or defects. The compound is allowed to air dry then typically sanded smooth before painting. Alternatively, for a better finish, the entire wall may be given a 'skim coat', a thin layer (about 1mm or 1/16inch) of finishing compound, to minimize the visual differences between the paper and mudded areas after painting.

Another similar skim coating is always done in a process called veneer plastering, although it is done slightly thicker (about 2mm or 1/8inch). Veneering uses a slightly different specialized setting compound ("finish plaster") that contains gypsum and lime putty. This application uses blueboard, which has special treated paper to accelerate the setting of the gypsum plaster component. This setting has far less shrinkage than the air-dry compounds normally used in drywall, so it only requires one coat. Blueboard also has square edges rather than the tapered-edge drywall boards. The tapered drywall boards are used to countersink the tape in taped jointing whereas the tape in veneer plastering is buried beneath a level surface. One coat veneer plaster over dry board is an intermediate style step between full multi-coat "wet" plaster and the limited joint-treatment-only given "dry" wall.

The method of installation and type of drywall can reduce sound transmission through walls and ceilings. Several builders' books state that thicker drywall reduces sound transmission, but engineering manuals recommend using multiple layers of drywall, sometimes of different thicknesses and glued together, or special types of drywall designed to reduce noise.[13] Also important are the construction details of the framing with steel studs, wider stud spacing, double studding, insulation, and other details reducing sound transmission. Sound transmission class (STC) ratings can be increased from 33 for an ordinary stud-wall to as high as 59 with double 1/2" drywall on both sides of a wood stud wall with resilient channels on one side and fiberglass batt insulation between the studs.[14]

Sound transmission may be slightly reduced using regular 58-inch panels (with or without light-gauge resilient metal channels and/or insulation), but it is more effective to use two layers of drywall, sometimes in combination with other factors, or specially designed, sound-resistant drywall.[15]

Drywall is highly vulnerable to moisture due to the inherent properties of the materials that comprise it: gypsum, paper, and organic additives and binders. Gypsum will soften with exposure to moisture, and eventually turn to a gooey paste with prolonged immersion, such as during a flood. During such incidents, some or all of the drywall in an entire building may need to be removed and replaced. Furthermore, the paper facings and organic additives mixed with the gypsum core are food for mold.

The porosity of the boardintroduced during manufacturing to reduce the weight of the board, lowering construction time and transportation costsenables water to rapidly reach the core through capillary action, where mold can grow inside. Water that enters a room from overhead may cause ceiling drywall tape to separate from the ceiling as a result of the grooves immediately behind the tape where the drywall pieces meet becoming saturated. The drywall may also soften around the screws holding the drywall in place and with the aid of gravity, the weight of the water may cause the drywall to sag and eventually collapse, requiring replacement.

Drywall's paper facings are edible to termites, which can eat the paper if they are infesting a wall cavity that is covered with drywall. This causes the painted surface to crumble to the touch, its paper backing material having been eaten. In addition to the necessity of patching the damaged surface and repainting, if enough of the paper has been eaten, the gypsum core can easily crack or crumble without it and the drywall must be removed and replaced.

In many circumstances, especially when the drywall has been exposed to water or moisture for less than 48 hours, professional restoration experts familiar with structural drying methodologies can introduce rapid drying techniques designed to eliminate necessary elements required to support microbial activity while also restoring most or all of the drywall and thus avoiding the cost, inconvenience, and difficulty of removing and replacing the affected drywall.

It is for these reasons that greenboard[16] and ideally cement board are used for rooms expected to have high humidity, primarily kitchens, bathrooms, and laundry rooms.

A substantial amount of defective drywall was imported into the United States from China and incorporated into tens of thousands of homes during rebuilding in 2006 and 2007 following Hurricane Katrina and in other places. Complaints included foul odour, health effects, and corrosion of metal within the structure. This is caused by the emission of sulphurous gases. The same drywall was sold in Asia without problems resulting,[citation needed] but U.S. homes are built much more tightly than homes in China, with less ventilation. Volatile sulphur compounds, including hydrogen sulphide, have been detected as emissions from the imported drywall and may be linked to health problems. These compounds are emitted from many different types of drywall.

A number of lawsuits are underway in many jurisdictions, but many of the sheets of drywall are simply marked, "Made in China", thus making identification of the manufacturer difficult. An investigation by the Consumer Product Safety Commission, CPSC, was underway in 2009.[17] In November 2009, the CPSC reported a "strong association" between Chinese drywall and corrosion of pipes and wires reported by thousands of homeowners in the United States. The issue was resolved in 2011 and now all drywall must be tested for volatile sulfur and any containing more than 10 ppm is unable to be sold in the US.

Drywall is made primarily from gypsum (CaSO42H2O). As its chemical formula shows, gypsum contains chemically combined water (approximately 50% by volume). When gypsum panels are exposed to fire, heat is absorbed as a portion of the combined water is driven off as steam. This chemical process is called calcination. The thermal energy that converts the water to steam is thus diverted and absorbed, keeping the opposite side of the gypsum panels cool as long as there is crystalline water left to be converted into steam or until the gypsum panel is breached. In the case of regular gypsum board, as the crystalline water is driven off, the reduction of volume within the gypsum core causes large cracks to form, eventually causing the panel to fail due to loss of structural integrity. This is similar to the cracking that can be observed in a dry lake or river bed.[18]

When used as a component in fire barriers, drywall is a passive fire protection item. In its natural state, gypsum contains the water of crystallization bound in the form of hydrates. When exposed to heat or fire, this water is vaporized, over a range of temperatures from 80 to 170C (see calcium sulphate), retarding heat transfer until the water in the gypsum is gone. This makes drywall an ablative material because as the hydrates sublime, a crumbly dust is left behind, which, along with the paper, is sacrificial. Generally, the more layers of Type X drywall one adds, the more one increases the fire-resistance of the assembly, up to four hours for walls and three hours for ceilings.[19] Evidence of this can be found both in publicly available design catalogues, including DIN 4102 Part 4 and the Canadian Building Code on the topic, as well as common certification listings, including certification listings provided by Underwriters Laboratories and Underwriters Laboratories of Canada (ULC). "Type X" drywall is formulated by adding glass fibres to the gypsum, to increase the resistance to fires, especially once the hydrates are spent, which leaves the gypsum in powder form. Type X is typically the material chosen to construct walls and ceilings that are required to have a fire-resistance rating.

Fire testing of drywall assemblies for the purpose of expanding national catalogues, such as the National Building Code of Canada, Germany's Part 4 of DIN4102 and its British cousin BS476, are a matter of routine research and development work in more than one nation and can be sponsored jointly by national authorities and representatives of the drywall industry. For example, the National Research Council of Canada routinely publishes such findings.[20] The results are printed as approved designs in the back of the building code. Generally, exposure of drywall on a panel furnace removes the water and calcines the exposed drywall and also heats the studs and fasteners holding the drywall. This typically results in deflection of the assembly towards the fire, as that is the location where the sublimation occurs, which weakens the assembly, due to the fire influence.

Cosponsored tests result in code recognized designs with assigned fire-resistance ratings. The resulting designs become part of the code and are not limited to use by any one manufacturer. However, individual manufacturers may also have proprietary designs that they have had third-party tested and approved. This is provided that the material used in the field configuration can be demonstrated to meet the minimum requirements of Type X drywall (such as an entry in the appropriate category of the UL Building Materials Directory or in the Gypsum Association Fire Resistance and Sound Control Design Manual) and that sufficient layers and thicknesses are used. Fire test reports for such unique third party tests are confidential but may be made available to code officials upon special request.

It's important to consider deflection of drywall assemblies to maintain their assembly integrity to preserve their ratings. Deflection of drywall assemblies can vary somewhat from one test to another. Importantly, penetrants do not follow the deflection movement of the drywall assemblies they penetrate. For example, see cable tray movement in a German test. It is, therefore, important to test firestops in full scale wall panel tests, so that the deflection of each applicable assembly can be taken into account.

The size of the test wall assembly alone is not the only consideration for firestop tests. If the penetrants are mounted to and hung off the drywall assembly itself during the test, this does not constitute a realistic deflection exposure insofar as the firestop is concerned. In reality, on a construction site, penetrants are hung off the ceiling above. Penetrants may increase in length, push and pull as a result of operational temperature changes (e.g., hot and cold water in a pipe), particularly in a fire. But it is a physical impossibility to have the penetrants follow the movement of drywall assemblies that they penetrate, since they are not mounted to the drywalls in a building.

It is, therefore, counterproductive to suspend penetrants from the drywall assembly during a fire test. As downward deflection of the drywall assembly and buckling towards the fire occurs, the top of the firestop is squeezed and the bottom of the firestop is pulled. This is motion above that caused by expansion of metallic penetrants due to heat exposure in a fire. Both types of motion occur because metal first expands in a fire, and then softens once the critical temperature has been reached, as is explained under structural steel. To simulate the drywall deflection effect, one can simply mount the penetrants to the steel frame holding the test assembly. The operational and fire-induced motion of the penetrants, which is independent of the assemblies penetrated, can be separately arranged.

Drywall provides a thermal resistance R-value (in US units) of 0.32 for 38-inch board, 0.45 for 12-inch, 0.56 for 58-inch, and 0.83 for 1-inch board. In addition to increased R-value, thicker drywall has a higher sound transmission class.[21][citation needed]

In Type X gypsum board, special glass fibers are intermixed with the gypsum to reinforce the core of the panels. These fibers have theeffect of reducing the size of the cracks that form as the water is driven off, thereby extending the length of time the gypsum panels resist fire without failure.[18]

Type C gypsum panels provide even greater fire resistance than Type X. As with the Type X panels, the core of the Type C panels contains glass fibers, only in a much higher percent by weight. In addition to the greater amount of glass fiber, the core of the Type C panels also contains vermiculite, which acts as a shrinkage-compensating additive that expands when exposed to elevated temperatures of a fire. This expansion occurs at roughly the same temperature as the calcination of the gypsum in the core. It allows the core of the Type C panels to remain dimensionally stable in the presence of fire, which in turn allows the panels to remain in place for a longer period of time even after the combined water has been driven off.[18]

North America is one of the largest gypsum board users in the world with a total wallboard plant capacity of 42,000,000,000 square feet (3.9109m2) per year (worldwide 85,000,000,000 square feet (7.9109m2) per year).[22] Moreover, the homebuilding and remodeling markets in North America in the late 1990s and early 2000s increased demand. The gypsum board market was one of the biggest beneficiaries of the housing boom as "an average new American home contains more than 7.31 metric tons of gypsum."[23]

The introduction in March 2005 of the Clean Air Interstate Rule by the United States Environmental Protection Agency requires power plants to "cut sulfur dioxide emissions by 73%" by 2018.[24] The Clean Air Interstate Rule also requested that the power plants install new scrubbers (industrial pollution control devices) to remove sulfur dioxide present in the output waste gas. Scrubbers use the technique of flue-gas desulfurization (FGD), which produces synthetic gypsum as a usable by-product. In response to the new supply of this raw material, the gypsum board market was predicted to shift significantly. However, issues such as mercury release during calcining need to be resolved.[25]

Because up to 12% of drywall is wasted during the manufacturing and installation processes and the drywall material is frequently not re-used, disposal can become a problem. Some landfill sites have banned the dumping of drywall. Some manufacturers take back waste wallboard from construction sites and recycle it into new wallboard. Recycled paper is typically used during manufacturing. More recently, recycling at the construction site itself is being researched. There is potential for using crushed drywall to amend certain soils at building sites, such as sodic clay and silt mixtures (bay mud), as well as using it in compost.[31] As of 2016, industry standards are being developed to ensure that when and if wallboard is taken back for recycling, quality and composition are maintained.